It is possible to configure the following system times:
•
Alarm
:
it is the alarm output activation time (sirens or other) in case of:
o
Burglar alarm, with armed system (Burglar outputs only).
o
Tamper alarm, also with disarmed system (Burglar outputs only).
o
Emergency alarm, also with disarmed system (Emergency outputs only).
o
Low battery/failure alarm, also with disarmed system (Low battery/failure alarm outputs only).
2 seconds time must be used exclusively for test purposes.
•
Entry (Pre-alarm
:
it is the delay time starting when the delayed input (input 1) detects an Burglar
attempt.
During this time, alarm signals, if present, are ignored, allowing people to enter in protected
premises to disarm, by keypad or key, the alarm system. Entry time is interrupted by disarming totally
or partially the system. During entry time, the keypad buzzer sounds intermittently. When entry time is
elapsed and the zone including the input 1 has not been deactivated, the control panel generates an
Burglar alarm.
•
Exit
:
it is the delay time starting when the system is partially or totally armed
;
when the time is
elapsed, the system is activated
.
During this time, alarm signals, if present, are ignored, allowing
people to leave the premises that will be protected by the alarm system
.
Exit time can be
interrupted
by disarming totally or partially the system. During exit time, the keypad buzzer sounds intermittently.
•
230 V mains fail alarm
:
it is the time that must elapse without 230 V power supply before the control
panel sends the related alarm vocal
message, SMS and with digital protocol (depending on message
kind, are required PSTN and GSM telephone lines, connections and a subscription with an alarm
reception centre). Time calculation is reset every time 230 V power supply is available again for 5
consecutive minutes. 1 minute time setting must be used exclusively for test purposes.
•
Technological alarm
:
it is the alarm outputs activation time (sirens and other), configured as
technological, in case of Technological alarm; alarm is generated also with disarmed system.