DS1061-036A
The keypads address is configured with their rotary switch and no other confirming operations are needed.
The address can have a value from 0 to 3 and must be unique for the group of keypads. It is suggested to
number in sequence the keypads during their installation. In a system can be present up to 4 keypads.
Figure 17 –
Position of rotary switch and valid addresses
If the keypad is installed in a flush mounting box, it must be protected against tampering by mounting on
the support the proper tamper (1069/416), that must be connected to the SAB input of the keypad. For
tamper can be used both available housings present on the support.
WARNING
:
The protection for tamper spring
Figure 19)
must be cut both when the keypad is installed
in the wall mounting box and in a flush mounting box.
If the keypad must be housed in the provided wall mounting box, follow the instructions below:
1. Open one or both the cable apertures (Figure 18, A).
WARNING
: In the wall mounting box are not present pre-fractured apertures for external tubes or
conduits.
2. Place the wall mounting box and mark the fixing holes
(Figure 18, B)
and the hole for the anti-removal tamper
(Figure 18, C).
3. Drill the wall with a 5mm bit, put the provided anchor screws and fix the wall mounting box. For a
correct installation, use 2 fixing holes at least and the hole for the tamper.
Figure 18 –
Wall mounting box for keypad
4. Cut the TAMPER protection on the keypad bottom to release the spring.
Figure 19 –
Tamper protection