10 FACTORY SETTINGS
To reset the control panel to factory settings (reset), follow the procedure below:
1.
Activate the system maintenance mode (see paragraph
7.1
MAINTENANCE PROCEDURE
).
2.
Open the control panel
.
3.
Keep the arrow button pressed for
10s.
4.
On the display appears the message
(reset default).
5.
Press
OK
button
.
6.
On the display appears the software version and then it blinks
.
7.
Insert a Master key or enter a Master code and keep on programming
.
NOTE:
The reset to factory parameters deletes ALL the settings previously present
.
CONTROL PANEL UNIT PARAMETERS
Connection mode of inputs and tamper line
Normally closed (NC) (programmable with JP1)
Inputs self by-pass
Disabled (programmable with JP2)
Inputs types
Line 1 delayed (not programmable)
Line 2-6 immediate (not programmable)
Inputs configuration
Burglar
Output 1
Burglar/tamper alarm
Output 2
Failure/Low battery alarm
Inputs association
All associated to associated to zone A
Auxiliary inputs association (Keypad)
All associated to associated to zone A
(not programmable)
Burglar alarm duration
60 seconds
Entry time
30 seconds
Exit time
30 seconds
Mains fail for 230 Vac mains fail alarm activation
1 hour
Technological alarm duration
30 seconds
Keys association
To all zones
Code association
To all zones
TELEPHONE COMMUNICATORS PARAMETERS
PSTN Module
Disabled
GSM Module
Disabled
Answer check
Disabled
Tones check
Disabled
Rings number for answer to incoming calls
0
Telephone line automatic tests
Disabled
Alarms/Telephone numbers association
No
SMS sending
Disabled
Type of message
Vocal