6.SETTING AND ADJUSTMENT OF READING
53
●
Cont. total
This mode controls the system so that the ratio of following two parameter values
maintains a constant value: 1) total amount of material conveyed from the start of
operation, 2) elapsed time from the start of operation. Depending on the setting in
[FEED UNIT], specify the target feed rate value in t/h or kg/h.
If you change the target value or clear the TOTAL, F805AT-BC starts from that point in
time to control the system so that the ratio is kept constant.
●
External entry
Use this function to specify Operation mode using external inputs (32 - 33 pins of control
connector).
Operation
Target value changes
Total ([t], [kg])
Total clear
0
Target value
Time
Actual total
Operation mode
(
0: CONT. FEED RATE, 1: FIXED,
2
1
0 – 3
2: AUTO COORDINATE, 3: CONT. TOTAL
)
Options: CONT. FEED RATE, FIXED, AUTO COORDINATE,
MODE
OPERATION
→
OPERATION MODE
→
PAGE×2
→
CONT. TOTAL, EXTERNAL ENTRY