9.OPTION (Option card required)
134
9-1-5. Polarity output (MUNUS)
This signal indicates the polarity of the BCD data.
0: positive (+), 1: minus (-)
9-1-6. Over status output (OVER)
This signal outputs 1 when one of the following conditions occurs in the BCD data.
9-1-7. Data strobe (STROBE)
BCD data is updated every time an A/D conversion takes place, and a strobe pulse is
output in synchronization with the conversion. Use rising edges to read in the BCD
data.
9-1-8. Hold input
Shorting this input to COM terminal holds the BCD output. The strobe pulses are also
suppressed.
9-1-9. Logic toggling input
This input toggles the signal logic between positive and negative.
Open: negative logic
Close: positive logic
Weighing value
Condition
Display
Belt speed
Belt Speed Over set value< belt speed
OFL1
Weight density
Weight Density Over set value< Weight
density
OFL2
Feed rate
Feed Rate Over set value<feed rate
OFL3
Load ratio
Load Ratio Over set value< load ratio
OFL4
Feed ratio
Feed Ratio Over set value< feed ratio
OFL5
Gross weight
A/D converter input over
LOAD,
-
LOAD
Total (upper 4 digits)
Total Final Over set value< total
TOTAL
FINAL
OVER
Total (lower 5 digits)
0
1
BCD data
STROBE
T
T’
T= data update rate
T’= strobe width