16.SETTING ITEMS LIST
178
Operation
Function
Setting Item
Initial value
NOV.
RAM
Lock
(
hard
)
Lock
(
soft
)
PASS
WORD
Input
method
Decimal
Place
Weighing Section
1000
◎
◎
◎
◎
Numeric
Arbitrary
Rated Feed Rate
45.00
◎
◎
◎
◎
Numeric
Arbitrary
Feed Unit
t/h , t
◎
◎
◎
◎
Selection 2
-
Operation Select
EXTERNAL
ENTRY
◎
◎
◎
◎
Selection 3
-
Rated Belt Speed
30.00
◎
◎
◎
◎
Numeric
Arbitrary
Dead Band Load Ratio
10
◎
◎
◎
◎
Numeric
None
Dead Band Belt Speed
10
◎
◎
◎
◎
Numeric
None
Dead Band
0.0
◎
◎
Numeric
1: fixed
Moisture Ratio
25
◎
◎
◎
◎
Numeric
None
Feed Pulse (W/P) 1
1kg
◎
◎
◎
Selection 5
-
Feed Pulse (W/P) 2
2*0.001
◎
◎
◎
Selection 12
-
Pulse Width 1
25
◎
◎
◎
Selection 5
-
Pulse Width 2
25
◎
◎
◎
Selection 5
-
Total W Disp. Digit
1g or 1kg
◎
◎
◎
Selection 4
-
Alarm Time
60
◎
◎
Numeric
None
Start Time
0
◎
◎
Numeric
None
First Stability Time
10
◎
◎
Numeric
None
Operation Mode
CONT. FEED
RATE
◎
Selection 5
-
Setting Item
Initial value
NOV.
RAM
Lock
(
hard
)
Lock
(
soft
)
PASS
WORD
Input
method
Decimal
place
Total Weight Clear
NO
◎
Command
-
START/STOP Key
VALID
◎
◎
Selection 2
-
Digital Zero
NO
◎
Command
-
Zero Tracking (Period)
0.0
◎
◎
◎
Numeric
1: fixed
Zero Tracking (Range)
0
◎
◎
◎
Numeric
None
DZ Regulation Value
2.00
◎
◎
◎
Numeric
Weight
Zero Error Key
VALID
◎
◎
◎
Selection 2
-
Weighing Code
Selection
KEY INPUT
◎
◎
Selection 2
-
I/O Monitor Display
INHIBIT
◎
◎
Selection 2
-
MODE
Operation
MODE
Function
Summary of Contents for F805AT-BC
Page 1: ...F805AT BC BELT SCALE CONTROLLER 15 Feb 2019 Rev 1 03 OPERATION MANUAL...
Page 15: ...CONTENTS XIV M E M O...
Page 202: ......