8.INTERFACE
124
8-4. D/A Converter [DAC]
The D/A converter provides F805AT-BC with the capability of sending internal
arithmetic data to the external devices using 4-20mA analog signal.
This analog signal ranges from zero (4mA) to full scale (20mA) as specified by two
parameters [D/A ZERO OUTPUT WEIGHT] and [D/A FULL SCALE VALUE].
Output terminal is electrically isolated from the internal circuit using a photo-coupler.
The D/A converter has 16-bit resolution and capable of 200 conversions per second.
This output is capable of over-range output (approx. ±10% FS).
Using the D/A converter, external pulse train is representing the belt speed which is
used as parameters for types of comparisons and readings.
8-4-1. External output port
Pin assignment
Source supply for external device
This output port provides power voltage for speed detecting devices such as a rotary
encoder. Power voltage is +12V, and capable of sourcing up to 160mA (6-pin).
Cur
rent [
m
A
]
0
25
50
75
100
Calculated value
Output [%]
4
8
12
16
20
D/A zero output
D/A full-scale
1
+
(ch1)
8
+
(ch2)
2
-
(ch1)
9
-
(ch2)
3
10
4
COM
11
COM
5
COM
12
COM
6
+12V
13
B-phase
7
Z-phase
14
A-phase
Note:
When used with F805AT-BC, pin No. 3 and 10 is not used and should
remain open. Applying external voltage to, or shorting these terminals may
result in failure/damage in the external device or F805AT-BC.