6.SETTING AND ADJUSTMENT OF READING
56
6-2-6. DZ regulation value
This value specifies the allowable range of zero-point correction (deviation from zero-
calibration), which is referenced by [DIGITAL ZERO] and Zero Tracking function.
Performing Digital Zero operation or Zero tracking outside the range,
comes on
in reverse-display (red) to notify the abnormal condition.
Operation
6-2-7. Z_ERR key
This function enables/disables the
key, which is used to perform ZERO
POINT AUTO ADJUSTMENT in the comparison and message screens.
Operation
6-2-8. Weighing code selection
This function selects the method (KEY INPUT, or EXTERNAL ENTRY) to specify the
CODE. If you select KEY INPUT, the CODE can be selected using
,
and
keys in EACH CODE screen.
If you select EXTERNAL ENTRY, CODE is specified by external signals (11 – 14 and
36-39 pins in the control connector).
* Currently selected CODE number is displayed (blue) in the upper pane of the EACH
CODE screen.
Operation
ZALM
Input range: 0 – 99.99 kg (4 digits, decimal place fixed)
MODE
FUNCTION
→
→
DZ REGULATION VALUE
Z_ERR
Options: INVALID, VALID
MODE
FUNCTION
→
→
ZERO ERROR KEY
▲
▲
OK
Options: KEY INPUT, EXTERNAL ENTRY
MODE
FUNCTION
→
→
WEIGHING CODE SELECTION