6.WEIGHING MODE SETTING AND OPERATION
67
6-2. Simple Comparison Control and Sequence Control
6-2-1. Simple Comparison Control
The simple comparison method compares the measured weight value with the
discharge setting at a regular interval. The system outputs “1” when the preset
condition is satisfied.
In this control method, the next control operation is only enabled when measured
weight falls below 75% of the previous Final value.
0
Near zero
Final - SP1
Final - SP2
Final - FF CPS.
Final
NET
Over
Under
Time
Near zero
SP1
SP2
SP3
Comparison
Compare time
Stable
Complete
Complete
OFF
ON
ON
ON
ON
ON
OFF
Over
Go
Under
ON
t3
t2
t1
t1
ON
inhibit time
output time