6.WEIGHING MODE SETTING AND OPERATION
71
・
Scheduling of "Complete" signal output is determined by parameter settings
for the complete signal output mode (Weighing function 2 parameters for
m+28CH).
・
Over/Under comparison is performed when complete output 1 is sent out and
the weight value at that moment is held. Thus, settings for Over/Under
comparison mode (Weighing function 2 parameters for m+28CH) are ignored.
・
Upper/Lower limit comparison is automatically performed at a regular
interval, ignoring settings for the Upper/Lower limit comparison mode
(Weighing function 2 parameters for m+28CH).
・
t1: Comparison inhibit time m+20CH
t2: Compare time
m+21CH
t3: Complete output time
m+22CH
・
Conditional expressions:
・
Near zero outputs "1" when Weight value <= Near zero set value
* Start signal's ON-edge (0
→
1) brings SP1, SP2, and SP3 outputs to "1".
・
SP1 outputs "0" when Weight value >= Final - SP1
・
SP2 outputs "0" when Weight value >= Final - SP2
・
SP3 outputs "0" when Weight value >= Final - FF. CPS
・
Under outputs "1" when Weight value < Final -Under
・
Over outputs "1" when Weight value > Final+Over
・
Go outputs "1" when Final+Over >= Weight value >= Final - Under
・
Near zero comparison uses either Gross or Net weight as a reference depending
on the Weighing function 1 settings for m+27CH.
・
Reference Weight value used for SP1/SP2/SP3 outputs and Over/Go/Under
comparison can be either Gross or Net weight depending on Weighing
function 1 settings for m+27CH.