6.WEIGHING MODE SETTING AND OPERATION
82
6-7. Complete Signal Output Mode / Complete Output Time /
Compare Time / Comparison Inhibit Time
Comparison inhibit time and Compare time
Proper operation of control systems can be adversely affected by mechanical
vibration induced by on/off actions of the valve. To avoid this effect, these two
parameters inhibit comparison operatio for a specific period of time.
Complete Signal Output Mode and Complete output time
These two parameters define the output timing of Complete signal and its
duration.
Complete signal outpu mode
Compare time/Comp.&Stable/Comp.or Stable
Complete output time
Input range: 0.00-9.99
Compare time
Input range: 0.00-9.99
Comparison inhibit time
Input range: 0.00-9.99
0
Final-SP1
Final-SP2
Final–FF CPS.
Comparison inhibit time
Compare time
0
Near zero
Final-SP1
Final-SP2
Final-FF CPS.
Final
NET
Over
Under
Time
Stable
Complete
Complete Time
ON
ON
Complete output time