6.WEIGHING MODE SETTING AND OPERATION
68
・
Triggering schedule of Over/Under comparison is determined by parameter
settings for the Over/Under comparison mode (Weighing function 2
parameters for m+28CH). The figure illustrates operation with “Regularly”
selected.
・
“
Complete" is output according to the conditions specified for the complete
signal output mode (Weighing function 2 parameters for m+28CH).
・
t1: Comparison inhibit time m+20CH
t2: Compare time
m+21CH
t3: Complete output time
m+22CH
・
Conditional expressions:
・
Near zero outputs "1" when Weight value <= Near zero set value
・
SP1 outputs "1" when Weight value >= Final - SP1
・
SP2 outputs "1" when Weight value >= Final - SP2
・
SP3 outputs "1" when Weight value >= Final - FF. CPS
・
Under outputs "1" when Weight value < Final -Under
・
Over outputs "1" when Weight value > Final+Over
・
Go outputs "1" when Final+Over >= Weight value >= Final - Under
・
Near zero comparison uses either signed values (Gross weight / Net weight) or
absolute values (|Gross weight| / |Net weight|) depending on the Weighing
function 1 settings for m+27CH.
・
Data used for SP1/SP2/SP3 outputs and Over/Go/Under comparison can be
either Gross or Net weight depending on Weighing function 1 settings for
m+27CH.