2.CONNECTION
11
<Connection of three 350
Ω
load cells in parallel>
㧹㧭㧯㧴
㧺㧜㧚
㧝㧜
㧝
㧝㧜
㧜
㨃㧱㧾㧾
㧻㨁㨀㧝
㧻㨁㨀㧞
㧾㨁㧺
㧱㧾㧯
㧱㧾㧴
㧲㧝㧡㧥
㧾㧿㨂
㧻㨁㨀㧝
㧻㨁㨀㧝
5
㧾㧿㨂
㧾㧿㨂
㧾㧿㨂
㧾㧿㨂
㧻㨁㨀㧞
㧻㨁㨀㧞
$
$
#
$
$
$
$
$
$
$
#
#
#
#
#
#
#
#
5
㧿㧴㧵㧸㧰
5+)
5+)
㧾㧿㨂
㧾㧿㨂
':%
㧙㧱㨄㧯
㧹㧭㧯㧴
㧺㧜㧚
㧝㧜
㧝
㧝㧜
㧜
㨃㧱㧾㧾
㧻㨁㨀㧝
㧻㨁㨀㧞
㧾㨁㧺
㧱㧾㧯
㧱㧾㧴
㧲㧝㧡㧥
㧾㧿㨂
㧻㨁㨀㧝
㧻㨁㨀㧝
5
㧾㧿㨂
㧾㧿㨂
㧾㧿㨂
㧾㧿㨂
㧻㨁㨀㧞
㧻㨁㨀㧞
$
$
#
$
$
$
$
$
$
$
#
#
#
#
#
#
#
#
5
㧿㧴㧵㧸㧰
5+)
5+)
㧾㧿㨂
㧾㧿㨂
':%
㧙㧱㨄㧯
㧹㧭㧯㧴
㧺㧜㧚
㧝㧜
㧝
㧝㧜
㧜
㨃㧱㧾㧾
㧻㨁㨀㧝
㧻㨁㨀㧞
㧾㨁㧺
㧱㧾㧯
㧱㧾㧴
㧲㧝㧡㧥
㧾㧿㨂
㧻㨁㨀㧝
㧻㨁㨀㧝
5
㧾㧿㨂
㧾㧿㨂
㧾㧿㨂
㧾㧿㨂
㧻㨁㨀㧞
㧻㨁㨀㧞
$
$
#
$
$
$
$
$
$
$
#
#
#
#
#
#
#
#
5
㧿㧴㧵㧸㧰
5+)
5+)
㧾㧿㨂
㧾㧿㨂
':%
㧙㧱㨄㧯
Power unit
PA205R
CPU unit
CJ1M-CPU11
Input unit
CJ1W-ID211
Output unit
CJ1W-OD211
F159
End cover
F159
F159
Three load cells are connected in parallel
0.58[A]
0.08[A]
0.10[A]
0.56[A]
0.56[A]
0.56[A]
Power consumption
→
Source capacity
5[V] 5[A]
Unit type
Unit name
Qty
Power consumption (A)
CPU unit
CJ1M-CPU11
1
0.58A
Input unit
CJ1W-ID211
1
0.08A
Output unit
CJ1W-OD211
1
0.10A
Weight Module
F159
3
1.68A
Consumption
(
A
)
Calculation
0.58
+
0.08
+
0.10
+
1.68
Result
2.44A
(≦
5A
)