77
4
SETTINGS AND CALIBRATIONS
77
SETTINGS AND CAL
IBRATIONS
Chapter
4
- Internal setting control
(displacement (Reference; Back))
t1: Delay time between the instant when the Start input is turned ON and the instant when all
outputs but Run are turned OFF ... Approx. 5ms
t2: Delay time between the instant when the Start input is turned OFF and the instant when the
measurable section is started. It varies depending on the time of crossing the Start Load.
t3: Delay time between the instant when the measurement is stopped (the Stop input is turned
ON) and the instant when the Result output is turned ON ... Approx. 50ms (However, there
are differences between measurements.)
t4: Delay time between the instant when the Result output is turned ON and the instant when
the Complete output is turned ON ... Approx. 30ms
Load
Displacement
Hold Result
Start load
Stop input
OFF
ON
Start input
OFF
ON
Complete output OFF
ON
OK output
Hold Result
LO or HI output
Measurement section
Calculating
Output OFF
Output OFF
OK is output if
Result is not LO or HI.
Result output
for Section 1 to 4
Section No. (set value)
Sct 1
Sct 2
Sct 3
Sct 4
P
E
P
S
P
E
P
S
P
E
P
S
P
E
P
S
Reset operation
t4
by the Start input
t3
t1
t2
SP:Start point
EP:End point
Result of the
previous
measurement
Result of the
previous
measurement
Previously
held value
Indicated
value
Sensor
input
value
Sct 4;
Sample
Sct 3;
Always
Sct 2;
Bottom
Sct 1;
Peak
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Page 164: ......