background image

  

CONTENTS

 

SAFETY PRECAUTIONS

 

GENERAL INFORMATION

 

WARNING

 

CAUTIONS

 

2

 

 

 

 

MODULE SPECIFICATIONS

 

STANDARDS

 

APPLICATION CLASS OF PRODUCT

 

FIRE CLASS OF PRODUCT

 

・ 

JUNCTION BOX AND TERMINALS

 

・ 

BYPASS DIODE

 

・ 

MECHANICAL LOADING

 

3

 

5

 

 

 

 

 

 

INSTALLATION

 

GENERAL

 

OPERATING CONDITIONS

 

SPECIAL CONDITIONS

 

UNPACKING AND HANDLING

 

MODULE INSTALLATION

 

6

 

 

 

 

 

7

 

WIRING

 

GENERAL

 

MODULE WIRING

 

ARRAY WIRING

 

EARTH GROUND WIRING

 

8

 

 

 

 

 

MAINTENANCE

 

ANTI

-

REFLECTION GLASS SURFACE CLEANING

 

DISPOSAL OF OLD EQUIPMENT

 

 

9

 

 

 

DISCLAIMER OF LIABILITY

 

CUSTOMER SERVICES

 

 

 

HIT

” 

is a trademark of the Panasonic Group.

 

Other product and service names listed in this manual are 
trademarks or registered trademarks of respective companies.

 

 

 

VBHNxxxSJ53, SJ54,

 

KJ01, KJ02 series

 

Photovoltaic Module HIT

TM

 

Thank you for choosing Panasonic photovoltaic module HIT

TM

. Please read this 

manual completely before you install or use HIT

TM

. With proper operation and 

maintenance, HIT

TM

 will provide you with clean, renewable solar electricity for 

many years. This manual contains important installation, maintenance and safety 
information. The word 

module

” 

as used in this manual refers to one or more PV 

modules. Retain this manual for future reference.   

 

Model No.

 

VBHN335SJ53, VBHN330SJ53, VBHN325SJ53, VBHN320SJ53

 

VBHN330SJ54, VBHN325SJ54, VBHN320SJ54

 

VBHN330KJ01, VBHN325KJ01, VBHN320KJ01

 

VBHN325KJ02, VBHN320KJ02

 

VBHNxxxSJ53/54 series

 

VBHNxxxKJ01/02 series

 

Summary of Contents for HIT KJ01 series

Page 1: ...mes listed in this manual are trademarks or registered trademarks of respective companies VBHNxxxSJ53 SJ54 KJ01 KJ02 series Photovoltaic Module HITTM Thank you for choosing Panasonic photovoltaic module HITTM Please read this manual completely before you install or use HITTM With proper operation and maintenance HITTM will provide you with clean renewable solar electricity for many years This manu...

Page 2: ...s are connected in series pro ducing higher voltages The shock hazard increases as modules with nominal open circuit voltage Voc in excess of 45 V and or modules rated for maxi mum system voltage in excess of 45 V Wear suitable clothing gloves and guards to prevent from direct contact with 30 VDC or greater Work only in dry conditions with dry modules and dry tools Children and unauthorized person...

Page 3: ...9 6 69 7 71 0 Short Circuit Voltage Isc 90 A 6 03 6 07 6 08 Maximum Power Voltage Vpm V 57 6 58 0 59 4 Maximum Power Current Ipm A 5 65 5 70 5 65 Temperature coefficient for Pmax 0 258 Temperature coefficient for Voc 0 235 Temperature coefficient for Isc 0 055 Cell Number in Series pcs 96 Cell Type Silicon hetero junction Maximum System Voltage Vsys V 1000 Maximum over current protection rating A ...

Page 4: ...Dimensions in mm Side The positions of the holes are all symmetrical against the center of the module Front side Section A A Section B B Back side Mounting location range L1 0 230 230 L2 450 380 345 S1 0 S2 250 Load resistance Positive load 2400 Pa 5400 Pa 2400 Pa 5400 Pa Load resistance Negative load 2400 Pa 4400 Pa 2400 Pa 5400 Pa Module locations and load resistance Depending on internal standa...

Page 5: ...graved onto the body of the junction box see Figure 2 BYPASS DIODE When the modules in series strings are shaded partially it may cause reverse voltage across cells or modules because the current from other cells in the same series is forced to flow through the shaded area This may cause unde sirable heating to occur The use of a diode to bypass the shaded area can minimize both heating and array ...

Page 6: ...exposed to moisture shall not be employed alone or in combinations that could result in deterioration or corrosion Clearance of 10cm between the roof surface and module frame is required to allow cooling air to circulate around the back of the module This also allows any condensation or moisture to dissipate Install modules so that air can circulate between the roof and the module Do not contact a...

Page 7: ...s that connect to ap propriate FUSE for each series string or each module For the installation of connection devices refer to the installation manual of connection devices Do not connect modules in parallel without maximum over current protection ARRAY WIRING The term array is used to describe the assem bly of several modules on a support structure with associated wiring When installing a PV array...

Page 8: ...lt water 3 Heavy snow falls areas 4 Sand and dust damage is excessive at the installa tion place Heavy dirt areas by sand or dust e g desert a quarry etc 5 Installation in places where there is a concern about deterioration of modules such as heavy air pollution chemically active vapors acid rain and or soot ammonia gas etc UNPACKING AND HANDLING Do not hit the back sheet of a module by the connec...

Page 9: ... caused by deter gents When cleaning the PV module please do not put detergent on the junction box or connector If detergents and chemical substances adhere the junction box and connectors may be deteri orated or damaged DISPOSAL OF OLD EQUIPMENT This symbol on the products and or accompanying documents means that used electrical and electronic products must not be mixed with general household was...

Page 10: ...10 Edition Revision Date Revised Item Revised Content TENTATIVE 2017 12 15 TENTATIVE 2 2017 12 20 Appearance drawing Fig 1 Change of Appearance drawing REVISION HISTORY ...