Measurement data
・
The sampling rate is fixed at 4000sps (samples per second).
・
Measurement is carried out at 4000sps, but the data kept in a waveform is 2000 pieces per the
Measurement Length. (Maximum data: 2048)
Therefore, the waveform resolution is the Measurement Length/2000.
When the Time/Displacement Change setting is Time
During measurement, the load is sampled at 4000sps, and after completion of the measurement, the
load by resolution is kept in a waveform.
Example) When the Measurement Length is 1.0s
When the Time/Displacement Change setting is Displacement
The load and displacement are sampled at 4000sps, and the load is kept in a waveform every time
the displacement advances.
Example) When the Measurement Length is 4000mm
When the displacement returns, all the data of the corresponding load is recognized as that of the
previous displacement.
Example) When the displacement returns
Load
Time
These data are kept
250
μ
s
Resolution(0.5ms)
in a waveform.
Resolution (0.5ms)
2.0ms
2.5ms
3.0ms
Load sampling: 4000sps (every 250
μ
s)
○
Load sampled by 250
μ
s
●
Load kept in a waveform
250
μ
s 250
μ
s 250
μ
s 250
μ
s 250
μ
s
Load
Displacement
These data are kept
Resolution (2mm)
in a waveform.
Resolution (2mm)
10mm
12mm
14mm
Load sampling: 4000sps (every 250
μ
s)
○
Load sampled by 250
μ
s
●
Load kept in a waveform
Load
Displacement
These data are kept
Resolution (2mm)
in a waveform.
Resolution (2mm)
10mm
12mm
14mm
Load sampling: 4000sps (every 250
μ
s)
○
Load sampled by 250
μ
s
●
Load kept in a waveform
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Page 164: ......