88
5
COMMUNICATIONS
88
COMMUNICA
TIONS
Chapter
5
②
Reading Y-axis Start Point after Work No. is written normally
- Set value write command (First Setting)
Example: Writing 1:10 [V] to Excitation Voltage, Y-axis Setting, First Setting
1
(
STX
)
Delimiter
N G
R
2
0
1
Delimiter
0
Host
F381A’s return
(In normal processing)
(Transmission to the F381A)
Item No. (See the list of set value commands.)
Y-axis Start Point in the example
Item group (See the list of set value commands.)
Display Range Setting in the example
(
STX
)
Delimiter
1
0
R
2
0
1
0
+
0
0
0
0
0
F381A’s return
(In abnormal condition)
Header (If there is no header, no data will result.)
NG No.
1: Receipt of a statement different from the command format
Data of the specified set value
Command received by the F381A
Header (If there is no header, no data will result.)
Host
F381A’s return
(In normal processing)
Command received by the F381A
Header (If there is no header, no data will result.)
(Transmission to the F381A)
Item No. (See the list of set value commands.)
Excitation Voltage in the example
Item group (See the list of set value commands.)
Y-axis Setting in the example
(
STX
)
Delimiter
0
0
W
1
0
0
0
+
0
0
0
1
0
0
0
+
0
0
0
0
0
0 1
W 0 1
Delimiter
Data to write
“1” in the example
(
STX
)
Delimiter
N
1
G
F381A’s return
(In abnormal condition)
Header (If there is no header, no data will result.)
NG No.
1: Receipt of a statement different from the command format
2: Attempt to write a set value outside the setting range
4: Attempt to write a set value through communications
during measurement
5: Attempt to write while protecting
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Page 164: ......