125
6
SYSTEM SETTINGS
125
SYSTEM SETTINGS
Chapter
6
⑨
SDC Check (Only when the SD card slot option is mounted)
Check the operation of the SD memory card.
Operation
Selectable range (Start, Err Clear)
Main screen
→
Setting
→
First Setting
→
System Setting
→
Self-Check
→
SDC Check
⑩
ETN Check (Only when the Ethernet I/F option is mounted)
The SDRAM, DPRAM, and LAN controller are checked.
If there is no error, OK is displayed, and if there is any error, NG
is displayed.
Also, the software version of the Ethernet I/F option is
displayed.
* Communication status is not checked. The IC is simply checked.
Operation
Selectable range (Start)
Main screen
→
Setting
→
First Setting
→
System Setting
→
Self-Check
→
ETN Check
⑪
Voltage Out Filter
Set whether or not to insert a filter in the previous step of the analog
monitor output (VOL OUT) of the load sensor.
Operation
Selectable range (OFF, ON)
Main screen
→
Setting
→
First Setting
→
System Setting
→
Self-Check
→
Vol. Out Filter
- Password
This setting is for maintenance and inspection. Do not operate it.
Operation
Setting range (0 to 9999)
Main screen
→
Setting
→
First Setting
→
System Setting
→
Password
- Time Adjust
Set the present time displayed on the Setting screen.
Setting range
Operation
(2000/01/01 00:00:00 to 2079/12/31 23:59:59)
Main screen
→
Setting
→
First Setting
→
System Setting
→
Time Adjust
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...