Measuring work specification
Up to 16 types of work set values can be stored in the F381A, and the work No. (measuring work)
used for measurement must be specified.
For this, the external input signals “Work 1 to Work 8” are used.
Normally, if there is no input to “Work 1 to Work 8,” the Work 0 set value is selected, while if
“Work 1 to Work 8” are in the following conditions, each work is selected.
(0:Open, 1:ON)
Work 8
Work 4
Work 2
Work 1
Main work display
(measuring work)
0
0
0
0
0
0
0
0
1
1
0
0
1
0
2
0
0
1
1
3
0
1
0
0
4
0
1
0
1
5
0
1
1
0
6
0
1
1
1
7
1
0
0
0
8
1
0
0
1
9
1
0
1
0
10
1
0
1
1
11
1
1
0
0
12
1
1
0
1
13
1
1
1
0
14
1
1
1
1
15
Control connector
A9, A10
B9, B10
COM (Input)
B1
Work 1
B2
Work 2
B3
Work 4
B4
Work 8
Measuring work is accepted when the Start
input signal is turned ON.
Even if the measuring work is changed
during measurement, it is ignored.
Point
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Page 164: ......