© 2004 by UniRac, Inc.
All rights reserved.
Pub 040625-3ii
July 2004
UniRac welcomes input concerning the accuracy and user friendliness of
this manual. Please write to
Series 5001 Single Row 3-Inch Pole Top
with SolarMount™ HD Rails
Installation Manual 524
U.S. and other patents pending.
Thank you for purchasing a UniRac. Please review this
manual com plete ly before proceeding.
This rack is intended for a 3-inch Schedule 40 steel
pole (O.D. 3
1
/
2
inches).
Assembly order is not critical. Work from the pole
outward or attach PV modules to rails before mount-
ing the array to the pole.
The installer is solely re spon si ble for:
• complying with all applicable building
codes, including any that supercede these
instructions;
• pole installation appropriate to local wind and
soil conditions;
• using only UniRac parts and installer-supplied
parts as specifi ed by UniRac (substitution of
parts will void the warranty);
• installing all electrical aspects of the PV array.
Parts List
Wrench Recommended
Part Qty. size torque (ft-lbs)
SolarMount rail 2
Cross pipe 1
Pole clamp 2
Pole cap 1
Hexhead bolt,
7
⁄
16
˝ 4
5
⁄
8
˝ 30
Lock washer,
7
⁄
16
˝ 4
Nut,
7
⁄
16
˝ 4
9
⁄
16
˝ 30
Saddle 2
U-bolt,
3
⁄
8
˝ 2
Flange nut,
3
⁄
8
˝ 4
9
⁄
16
˝ 30
Module mounting clip 4*
Module bolt,
1
⁄
4
˝ 4*
7
⁄
16
˝ 15
Flange nut,
1
⁄
4
˝ 4*
7
⁄
16
˝ 15
*Per module to be mounted. Series 5001 racks include clips and hardware to mount 2 to 6 modules.
Caution
Stainless steel hardware can seize up, a process
called galling. To sig nifi cant ly reduce the like li hood
of galling, apply a small drop of anti-seize lubricant
to the threads of all bolts before installation.
Anti-seize lubricants are readily available in auto
parts and hardware stores. In their absence, any
lubricant will reduce chances of galling.
Note: Parts are illustrated in exploded views (pp. 2–4).