3.6.3. Wiegand Settings
Wiegand support is available in the terminal. In the back of the AC6000 there are terminals for
Wiegand IN0 and Wiegand IN1, Wiegand OUT0 and Wiegand OUT1.
Wiegand Connection Option 1
When using an external reader that supports wiegand you can connect the reader to Wiegand IN0
and Wiegand IN1. This will allow the reader data to be sent to the AC6000 terminal.
IN0 = Data0
IN1 = Data1
Wiegand Connection Option 2
When using an external controller that supports wiegand, you can use the AC6000 as a dummy
reader. The AC6000 will send the site code and user id to the external controller.
OUT0 = Data0
OUT1 = Data1
3.6.3.1. Site Code
The site code is a unique three digit value that should be different for every terminal. Values are
from 0-255. To program this value just touch the number field and a number pad will appear, enter
the value and press OK.
3.6.3.2. Format
There are many different formats for wiegand. Select the appropriate format that your external
controller or reader supports.