4.3 Choosing the probe location
The installation depends on the type of probe.
4.3.1 Intrusive probes
Two geometric modes may be applied:
o
Diametric mode:
The chord follows the diameter of the cross-section. An approach by Kh is then
activated in order to model he speed profile and refine the measurement. The Kh coefficient takes
account of the roughness of the wall and the viscosity of the fluid. You are strongly recommended
to refer to the teaching manual available on request in order to understand the significance of
these settings.
o
Parallel mode:
The chords are placed in parallel planes which "section" the
fluid speed flow better.
Note:
The accuracy of the measurement is improved by increasing the number of chords.
Important:
With a "simple" configuration, diametric mode must be used. Parallel mode is available from
"normal" configuration level.
For each chord, enter the length (in meters) between the faces of the two probes. To help you, read our
document “Ultrasonic transit time flowmeter”.
Also enter the projected length (Daxe) of this measurement relative to the axis of the pipe.
Summary of Contents for Uf 841
Page 4: ...4 NT UF 841 CP GB d June 2015 CHAPTER 1 OVERVIEW...
Page 12: ...12 NT UF 841 CP GB d June 2015 CHAPTER 2 SAFETY INSTRUCTIONS...
Page 17: ...17 NT UF 841 CP GB d June 2015 CHAPTER 3 INSTALLATION AND WIRING...
Page 25: ...25 NT UF 841 CP GB d June 2015 CHAPTER 4 INSTALLING A MEASURING POINT...
Page 27: ...27 NT UF 841 CP GB d June 2015...
Page 35: ...35 NT UF 841 CP GB d June 2015 CHAPTER 5 USING AND CONFIGURING THE Uf 841...
Page 64: ...64 NT UF 841 CP GB d June 2015 CHAPTER 6 FUNCTION ENGINE...
Page 68: ...68 NT UF 841 CP GB d June 2015 CHAPTER 7 PC SOFTWARE...
Page 82: ...82 NT UF 841 CP GB d June 2015 Appendix I Characteristic echo signals...
Page 85: ...85 NT UF 841 CP GB d June 2015 Appendix II Speed of sound in water...