19
NT UF 841 CP GB (d) / June 2015
For installation on piping, you may use stainless steel straps to attach the unit, passing them through the
oblong holes designed for this purpose. With regard to flat surfaces, the following holes should be made:
Holes should be of 9 mm diameter for bolt attachment. Support tapping is also possible. In this case, ISO
M8 threaded holes must be made.
To facilitate installation of the unit, please follow the steps below:
-
Attach the unit to the selected support using ISO M8 screws,
-
Open the entire unit (tube + front cover) to access the board connectors,
-
Connect the protective ground (see chapter 3.5),
-
Pass the various cables through the cable glands,
-
Connect the cables to the various terminals (see chapter 3.6),
-
Tighten the cable glands (for the tightening torques, please refer to the cable gland user
instructions).