PROBLEM
POSSIBLE CAUSE
SOLUTION
TROUBLESHOOTING GUIDE
Meter won't turn on
Dead batteries
Replace batteries.
Seal to electronic chamber
Damaged or contaminated Replace electronics module
is broken if display label is
electronics module
& gaskets.
removed or punctured.
Flashing decimal
Current total has rolled
Reset meter (if desired).
Meter will continue to
over
operate normally.
Flashing or
Low batteries
Replace batteries.
Use alkaline batteries.
dim display
Leaking fluid at
Need thread sealant
Add Teflon pipe tape to joint.
inlet/outlet port
Cross-threaded port
Replace body.
Fluid flows; meter
Meter disk sticking
Clean out meter chamber.
won't count
Damaged driver
Repair or replace chamber assembly.
or magnet
Meter failure
Repair or replace meter.
Meter reads high
Air in system
Prime system, fix suction leak at pump. Meter will count air.
Wrong calibration factor
Use a higher calibration factor.
Chemical formulations
Sometimes change.
Check fluid temperature
Meter reads low
Wrong calibration factor
Use a lower calibration factor.
Chemical formulations
Check fluid temperature.
Sometimes change.
Meter chamber is worn
Recalibrate meter with water.
Damaged or very worn
Replace chamber and recalibrate
chamber
meter.
Meter is not
Air in system
Prime system, fix suction leak at pump.
consistent
Particulates in fluid
Put screen in front of meter.
40 mesh minimum.
Meter has worn or
Replace chamber.
damaged chamber
Err0
Calibration error
Recalibrate meter with more accurate Indicates fluid calibration is
container.
out of acceptable window.
Damaged chamber
Replace chamber.
Volumetric container may
be off, there may be air in
the system, or the meter
chamber may be dam-
aged.
Err1
Damaged electronics
Repair or replace electronics.
Software fault
Press 2 then recalibrate meter
Contact factory