5-5
SECTION 5
TEST RESULTS
RX FREQ, Hz
Received Frequency in Hz
— The frequency
of the clock measured from the received data.
The valid range for received frequency is from
1539000 Hz to 1549000 Hz. If the RX FREQ,
Hz result exceeds the maximum value >1549000
is displayed. If the RX FREQ, Hz result is less
than the minimum value <1539000 is displayed.
TIMING SLIP
Timing Slips
— The number of bit slips and
framing slips counted when the RX jack input
has slipped from the REF jack input. Timing
slips are displayed as the number of framing
slips and the number of bit slips. Each framing
slip equals 193 bit slips. The framing slip total is
displayed in the third line of the RESULTS
display in a range from -999 to +999. The bit slip
total is displayed in the bottom line of the
RESULTS display in a range from -192 to +192.
In addition to the test results, the following
status messages appear in the SUMMARY category
as required.
ALL RESULTS OK
—
This message is displayed
when all summary results are error-free or meet
specification boundaries.
ALL RESULTS UNAVAILABLE
—
This message is
displayed when T1 signal presence has not been
detected since test restart.
Summary of Contents for T-BERD 107A