5-8
SECTION 5
TEST RESULTS
USER
User BPM Detected
— A received BPM stat-
ing the signal is recognized as an eight-bit
user-programmable BPM.
The following SUMMARY category alarm and
maintenance messages act as a current indication of
the messages that are received from the SLC-96
datalink. The SLC Datalink Decode Option is re-
quired for these messages.
MAJOR ALARM SHELF x
Major Alarm on Shelf x
—
This message is
displayed when a major alarm is detected with
an accompanying alarm on the indicated shelf (x
= A, B, C, or D).
MAJOR ALARM NO SHELF
Major Alarm, No Shelf
—
This message is
displayed when a major alarm is detected with-
out an accompanying shelf alarm.
ALARM SHELF x
Shelf Alarm on Shelf x
—
This message is
displayed when a shelf alarm condition exists on
the indicated shelf (x = A, B, C, or D) without an
accompanying major alarm.
FE LOOP SHELF x
Far-End Loop on Shelf x
—
This message is
displayed when a request is sent to the far end to
loop the indicated shelf (x = A, B, C, or D).
FE LOOP PROTECT
Far-End Loop on Protection Line
—
This
message is displayed when a request is sent to
the far end to loop the protection shelf.