27
5-4 Page4 Digital limit switch setting
1.
: SETUP channel selection
Same as Page 1.
2.
: Digital limit switch ENA/DIS default: ENA
Set enable or disable of digital limit switch.
It will be set simultaneously in CW / CCW direction.
If enabled, when the CCWLS value less than or more than the CWLS value, it does
not work in that direction.
ENA:
Digital limit switch is enabled.
DIS:
Digital limit switch is disabled.
3.
: Digital limit switch value
Setting range
: -2,147,483,647 ~ +2,147,483,647
Initial
value: CW/+1,000,000 CCW/-1,000,000,
Set the limit value when digital limit switch is enabled with numeric keypad.
4.
:Backlash data Setting range:-9999 ~ +9999 Initial value:+100
You can set the amount of backlash movement to be performed in remote mode with
numeric keypad.
For digital limit switch
In the case of CWLS, digital limit switch is activated when it exceeds the set value, the
motor will not work in that direction. In the case of CCWLS, digital limit switch is
activated when it becomes less than the set value, the motor will not work in that
direction.
Since entering the stop operation at the time the digital limit switch is on, it will overrun
the set value if the speed setting is fast. It does not mean that we are guaranteeing the
motor will not move out of range of the limit switch, set the value to be able to secure a
sufficient stop interval when setting.
C
H
:
0
0
D
I
G
I
T
A
L
L
S
P
4
C
W
:
D
I
S
0
1
2
3
4
5
6
7
8
9
-
C
C
W
:
D
I
S
-
0
1
2
3
4
5
6
7
8
9
□
B
A
C
K
L
A
S
H
:
-
9
9
9
9
9
3
4
2