8 Timing out signal output
57
Output method
1.
Set the timing signal
In LOCAL mode, please refer to “Page7 TIMING OUT setting” (page28) for setting.
In REMOTE mode, you can be set by the following commands.
<ch>: 0 ~ F(Hexadecimal) for channel
Command TMGM<ch><type>
Select type of timing signal.
Argument <type>
Type of signal
0/ no signal
1/ GATE signal
2/ 200ns pulse
3/ 10us pulse
4/ 100us pulse
5/ 1ms pulse
6/ Manual level output
7/ manual 1us pulse output
8/ manual 10us pulse output
9/ Manual 100us pulse output
A/ Manual 1ms pulse output
Reply nothing
Example TMGM15
Remarks
Only remote mode
Item that is shaded is the default parameter settings at reset.
Command TMGM?<ch>
Confirm type of timing signal.
Reply
0 ~ A (HEX
1-digit integer
) please refer to ”TMGMx” <type> for
meaning.
Example TMGM?2 reply: 1
Remarks
Command TMG<md>?<ch>
Read out the timing signal start point, or the timing signal
end point.
Argument <md>
mode
S/ start point E/ end point
Reply
±
ddddddd (
Signed 7-digit integer
)
Example TMGE?2 reply: +0050000
Remarks
Command TMGI<ch><data>
Set the interval of the timing pulse output.
Argument <data>
interval
1 ~ 2,147,483,647
Initial value 200
Reply Nothing
Example TMGIF1000
CH-F's the interval of timing pilse will be set to 1000.
Remarks Only remote mode