Tradedor TD55DM & TD55SEL Installation Guide
11
1
Remove the lid of the receiver box by
unscrewing small screw at bottom
(fig 5.1 A)
and then sliding the lid up, being careful to
remove plug-in cable from board
(fig 5.1 C)
.
2
Place the Receiver box on the wall with the
cable pointing downwards at a comfortable
height to operate the push buttons, but out of
the easy reach of children. Between 1500mm
up from the floor and 300mm down from the
roof/ceiling is recommended.
3
Making sure the box is square, mark
the two fixings (one top and one bottom),
then drill and secure with fixings
(fig 5.1 B)
.
4
For ease of installation, undo the terminal
clamp at the bottom
(fig.5.1D)
.
5
Wiring as follows
(fig.5.2
&
fig.5.3)
;
Pre wired Mains Power:
N – Neutral / Blue power cable
L – Live / Brown power cable
Earth – Earth power cable
Motor:
L – Brown motor cable (4 core)
R – Black motor cable (4 core)
Earth – Earth connection motor
cable (4 core)
N – Blue motor cable (4 core)
SPECIAL ATTENTION:
red link wire
from G to U and G to S
MUST STAY IN
fig.5.2
fig.5.3
230v TUBE MO-
TOR CONNECTION
Connect tube motor
where shown
Note: This connection will
supply 230v AC and is
specifically for tube motor
operation
Tube Motor 230v AC 50Hz
Mains Supply
230v AC 50Hz
Stop
Gn/Yl
Brown
Blue
Mains Supply Connection
AC IN
N L
Connect mains
power supply
where shown
Recommended
Power Supply
Protection:-
13A fused Spur or
Single Pole
connected
protected by MCB
Type 'A
'
Ext Key-Switch Connection
Close
Open
Com
Ext Push Button Connection
Open
Close
L
R
N
Motor Direction
Motor Earth
Motor Common
Motor Direction
Terminal Connections
U D G
V
U S
MANUAL PHOTOCELL
24v dc
Reflective
Photocell
0v
U D
G V U S
MANUAL PHOTOCELL
24v DC Photocell Connection
+24v
N/C
com
U D G
V
U S
MANUA PHOTOCELL
N
L
Mains Power 230v AC (Live)
Mains Power 230v AC (Neutral)
Mains Power (Earth)
U
External connection - Open
D
External connection - Close
V
+24v dc
G
0V / Switch Common / Photocell Common
Photocell connection - N/C contact
External connection - Stop
Mains Supply
Motor
Manual
Photocell
Basic Remote Control Operation
U D
G
V
U S
MANUAL PHOTOCELL
External
Push Button
Connection
Safety Brake Connection
U D
G
V
U S
MANUAL PHOTOCELL
Safety Brake
(N/C) Switch
Connection
MOTOR
L R N
230v Tube Motor Connection
Gn/Yl
Black
Brown
Blue
Connect tube
motor where
shown
Note:
This connection
will supply
230v
AC and is
specifically
for tube motor
operation
Tube Motor
230v AC 50Hz
MOTOR
L R
Volt free Switching Connection
N
Connection to
provide a 'volt
free' switching
operation
Com
Close
Open
To add an additional external
push button station
Connect where shown leaving link
fitted between G + U
To add an additional external
key-switch
Connect where shown leaving link
fitted between G + U
+ S
To add an additional photocell for
safety
Connect where shown leaving
links fitted between G + S
Activating the photocell will stop
and re-open a closing door
External
Key switch
Connection
Date
Drawn by
Chk'd by
Drg #
Title
Ellard House
Floats Road
Roundthorn Industrial Estate
Wythenshawe, Manchester
M23 9WB
Tel: 0161 945 4561
Fax: 0161 945 4566
This drawing is the property of ELLARD LTD, it may not be reproduced without the written authorisation of Ellard Ltimited. All interlecual property rights are expressly reserved
Revision / Notes:
04/07/2018
D. England
J. Monks
This is a special connection that
does not provide a voltage output
The unit must be factory modified
to give this function and will be
marked 'Volt Free' as such
For Basic remote Control
Operation
Leave links fitted between
G + U + S
Connect safety brake where
shown
Leave link fitted between
U + S
Connection Detail For
ATHENA 2nd GEN
(White Enclosure/White Transmitter)
elec-ATHENA2-001A
Com
MAINS SUPPLY
CONNECTION
Connect mains power supply
where shown
Recommended Power Supply
Protection:- 13A fused Spur
or Single Pole connected
protected by MCB Type 'A'
Mains Supply 230v AC
50Hz
Mains Supply
230v AC 50Hz
Stop
Gn/Yl
Brown
Blue
Mains Supply Connection
AC IN
N L
Connect mains
power supply
where shown
Recommended
Power Supply
Protection:-
13A fused Spur or
Single Pole
connected
protected by MCB
Type 'A
'
Ext Key-Switch Connection
Close
Open
Com
Ext Push Button Connection
Open
Close
L
R
N
Motor Direction
Motor Earth
Motor Common
Motor Direction
Terminal Connections
U D G
V
U S
MANUAL PHOTOCELL
24v dc
Reflective
Photocell
0v
U D
G V U S
MANUAL PHOTOCELL
24v DC Photocell Connection
+24v
N/C
com
U D G
V
U S
MANUA PHOTOCELL
N
L
Mains Power 230v AC (Live)
Mains Power 230v AC (Neutral)
Mains Power (Earth)
U
External connection - Open
D
External connection - Close
V
+24v dc
G
0V / Switch Common / Photocell Common
Photocell connection - N/C contact
External connection - Stop
Mains Supply
Motor
Manual
Photocell
Basic Remote Control Operation
U D
G
V
U S
MANUAL PHOTOCELL
External
Push Button
Connection
Safety Brake Connection
U D
G
V
U S
MANUAL PHOTOCELL
Safety Brake
(N/C) Switch
Connection
MOTOR
L R N
230v Tube Motor Connection
Gn/Yl
Black
Brown
Blue
Connect tube
motor where
shown
Note:
This connection
will supply
230v
AC and is
specifically
for tube motor
operation
Tube Motor
230v AC 50Hz
MOTOR
L R
Volt free Switching Connection
N
Connection to
provide a 'volt
free' switching
operation
Com
Close
Open
To add an additional external
push button station
Connect where shown leaving link
fitted between G + U
To add an additional external
key-switch
Connect where shown leaving link
fitted between G + U
+ S
To add an additional photocell for
safety
Connect where shown leaving
links fitted between G + S
Activating the photocell will stop
and re-open a closing door
External
Key switch
Connection
Date
Drawn by
Chk'd by
Drg #
Title
Ellard House
Floats Road
Roundthorn Industrial Estate
Wythenshawe, Manchester
M23 9WB
Tel: 0161 945 4561
Fax: 0161 945 4566
This drawing is the property of ELLARD LTD, it may not be reproduced without the written authorisation of Ellard Ltimited. All interlecual property rights are expressly reserved
Revision / Notes:
04/07/2018
D. England
J. Monks
This is a special connection that
does not provide a voltage output
The unit must be factory modified
to give this function and will be
marked 'Volt Free' as such
For Basic remote Control
Operation
Leave links fitted between
G + U + S
Connect safety brake where
shown
Leave link fitted between
U + S
Connection Detail For
ATHENA 2nd GEN
(White Enclosure/White Transmitter)
elec-ATHENA2-001A
Com
SAFETY BREAK
CONNECTION
Connect safety brake
where shown
Safety Break (N/C) Switch
Connection
Mains Supply
230v AC 50Hz
Stop
Gn/Yl
Brown
Blue
Mains Supply Connection
AC IN
N L
Connect mains
power supply
where shown
Recommended
Power Supply
Protection:-
13A fused Spur or
Single Pole
connected
protected by MCB
Type 'A
'
Ext Key-Switch Connection
Close
Open
Com
Ext Push Button Connection
Open
Close
L
R
N
Motor Direction
Motor Earth
Motor Common
Motor Direction
Terminal Connections
U D G
V
U S
MANUAL PHOTOCELL
24v dc
Reflective
Photocell
0v
U D
G V U S
MANUAL PHOTOCELL
24v DC Photocell Connection
+24v
N/C
com
U D G
V
U S
MANUA PHOTOCELL
N
L
Mains Power 230v AC (Live)
Mains Power 230v AC (Neutral)
Mains Power (Earth)
U
External connection - Open
D
External connection - Close
V
+24v dc
G
0V / Switch Common / Photocell Common
Photocell connection - N/C contact
External connection - Stop
Mains Supply
Motor
Manual
Photocell
Basic Remote Control Operation
U D
G
V
U S
MANUAL PHOTOCELL
External
Push Button
Connection
Safety Brake Connection
U D
G
V
U S
MANUAL PHOTOCELL
Safety Brake
(N/C) Switch
Connection
MOTOR
L R N
230v Tube Motor Connection
Gn/Yl
Black
Brown
Blue
Connect tube
motor where
shown
Note:
This connection
will supply
230v
AC and is
specifically
for tube motor
operation
Tube Motor
230v AC 50Hz
MOTOR
L R
Volt free Switching Connection
N
Connection to
provide a 'volt
free' switching
operation
Com
Close
Open
To add an additional external
push button station
Connect where shown leaving link
fitted between G + U
To add an additional external
key-switch
Connect where shown leaving link
fitted between G + U
+ S
To add an additional photocell for
safety
Connect where shown leaving
links fitted between G + S
Activating the photocell will stop
and re-open a closing door
External
Key switch
Connection
Date
Drawn by
Chk'd by
Drg #
Title
Ellard House
Floats Road
Roundthorn Industrial Estate
Wythenshawe, Manchester
M23 9WB
Tel: 0161 945 4561
Fax: 0161 945 4566
This drawing is the property of ELLARD LTD, it may not be reproduced without the written authorisation of Ellard Ltimited. All interlecual property rights are expressly reserved
Revision / Notes:
04/07/2018
D. England
J. Monks
This is a special connection that
does not provide a voltage output
The unit must be factory modified
to give this function and will be
marked 'Volt Free' as such
For Basic remote Control
Operation
Leave links fitted between
G + U + S
Connect safety brake where
shown
Leave link fitted between
U + S
Connection Detail For
ATHENA 2nd GEN
(White Enclosure/White Transmitter)
elec-ATHENA2-001A
Com
B
B
D
C
A
fig.5.1
6. Installing Reciever Box
(HOLD TO RUN)
- TYPE 2
Summary of Contents for TD55DM
Page 1: ...Tradedor TD55DM TD55SEL Installation Guide TD55DM TD55SEL Installation Guide...
Page 2: ...Tradedor TD55DM TD55SEL Installation Guide 1 Installation Guide Finished door...
Page 9: ...Tradedor TD55DM TD55SEL Installation Guide Finished door from inside 8...
Page 19: ...Tradedor TD55DM TD55SEL Installation Guide fig 9 1 fig 9 2 fig 9 3 18...
Page 38: ...Tradedor TD55DM TD55SEL Installation Guide Notes...
Page 39: ...Tradedor TD55DM TD55SEL Installation Guide Notes...