TOSHIBA
4.2
Selection of Main Circuit Wiring Equipment and
Standard Cable Sizes
4 - 5
*Molded case
Ampacity
Inverter
circuit breaker (FLA x 1.25)
**Typical cable size (AWG)
(MCCB)
Amp
Main power
230Vac and
Frequency
Other
Type form
rating
(A)
and
460Vac control
command input,
signal
(A)
motor load
power source
frequency meter,
circuits
ammeter
G2+2010
15
4
#14
G2+2015
15
5.1
#14
G2+2025
20
9.8
#14
G2+2035
20
13.8
#14
G2+2055
30
21.9
#12
G2+2080
50
31.6
#10
G2+2110
70
40
#8
G2+2160
90
60
#6
G2+2220
100
78
#4
G2+2270
125
98
#3
G2+2330
150
115
#2
G2+4015
15
2.5
#14
#14
3-core shield cable
#18
(speed reference)
G2+4025
15
4.9
#14
2-core shield cable
#20
G2+4035
15
6.9
#14
G2+4055
15
10.9
#14
G2+4080
30
15.8
#14
G2+4110
30
20.1
#12
G2+4160
40
30.2
#10
G2+4220
50
38.8
#8
G2+4270
70
48.8
#8
G2+4330
90
57.5
#6
G2+4400
100
74.8
#4
G2+4500
100
93.4
#3
G2+4600
125
110.7
#2
G2+4750
175
138
#1/0
G2+410K
200
178.3
#3/0
G2+412K
225
224.3
#4/0
G2+415K
300
258.8
*** 2 (#2/0)
G2+420K
350
345
*** 2 (#4/0)
G2+425K
400
428
*** 2(#4/0)
G2+430K
600
472
*** 2(#350)
See next page for notes.