Function Access/Set - Status Keys
Note:
Each key (0-9) has three separate functions: numerical value, first function,
and second function. See Operating Panel (Section 6.1)
Key
Function
Toggles between the
monitor
and
function
mode.
Switches to the second function mode.
Used to initiate several functions (ie. JOG, Preset Run, Pattern Run).
Displays the next item within the function. Also cycles through the inverter's
status codes.
Clears the display. Also clears inverter after a trip.
(Must press CLR/WRT to reset inverter after a trip)
Stores each piece of data into the inverters memory (file).
"." is a decimal point.
"READ" displays the inverter's data contents for an individual function.
"0" is the numerical zero.
1st FUNCTION MODE:
Selects the
standard setting mode
. Also sets the
maximum frequency
(disabled during a run).
2nd FUNCTION MODE:
Sets the
start-up
frequency
and
run frequency
.
Also sets the
run frequency hysteresis
.
"1" is the numerical one.
1st FUNCTION MODE:
Sets the voltage
boost
,
auto torque boost
,
maxi-
mum
voltage frequency
, and
V/F pattern
.
2nd FUNCTION MODE:
Sets the
DC injection starting frequency
,
DC
injection voltage
, and
DC voltage injection time
.
"2" is the numerical two.
1st FUNCTION MODE:
Sets the
ACC/DEC time
for ACC 1, 2 and DEC 1, 2.
Selects the
ACC/DEC pattern
for 1, 2.
Selects
ACC/DEC 1 or 2
.
2nd FUNCTION MODE:
Sets the multiply factor of
display frequency scaler
.
"3" is the numerical three.
1st FUNCTION MODE:
Sets
upper and lower frequency limits
.
2nd FUNCTION MODE:
Sets low speed detection output.
Selects speed reach selection output option.
Sets
speed reach detection
range and
speed reach
reference
frequency.
"4" is the numerical four.
1st FUNCTION MODE:
Sets
overload detection level
(% of rated current),
stall activation level
, and also selects the
overload
detection curve
characteristics.
2nd FUNCTION MODE:
Sets the
output voltage adjustment
(% of input
voltage).
Selects the
dynamic braking resistor
option and the
OLr option
.
Selects the
auto deceleration option
when no
dynamic braking resistor is used.
6 - 5
.
WRT
UL/LL
3
ACC/DEC
2
V/F
1
FMAX
0
READ
NEXT
2ND
MON
OL
4
CLR