TOSHIBA
Pattern run activation
0: Off
0
8-28
mode
1: Terminal operation
2: Touch pad operation
3: Computer communication
Time unit
0: Seconds
0
8-28
1: Minutes
Cycle times
0 to 255
0
8-28
(255: Infinity operating)
Function Function
Adjustment
Factory
Error
Ref.
No.
Name
Display
Range
Unit
Set
Message
Page
5.6
Programmable Run Patterns
Sr1
Sr2
Pattern 3 (DEC #1 or #2)
Sr4
Time
Sr5
Pattern 5
Pattern 4
Pattern 3
Pattern 2
Pattern 1
Sr3
Pattern 1 (ACC #1 of #2)
Pattern 2 (ACC #1 or #2)
Pattern 3 (ACC #1 or #2)
Pattern 4 (DEC #1 or #2)
Pattern 5 (ACC #1 or #2)
Pattern 5 (DEC #1 or #2)
Pt.2
Pt.4
Pt.5
Pt.1t
Pt.2t
Pt.3t
Pt.4t
Pt.5t
Pt.1
Pt.3
Pt.3
·
Up to 7 different preset speed patterns can be automatically executed to produce
what is known as a Pattern Run.
·
Each speed can be set to operate in the range of 0 to 8000 seconds or minutes.
·
Each pattern can be set to accelerate/decelerate using either one of the two
acceleration/deceleration functions.
·
Each pattern can be set to operate in either the forward or reverse direction.
.
Pattern may be repeated 0 to 254 times or repeat infinitely.
1st speed
LL to UL setting value
Hz
0
8-23
2nd speed
LL to UL setting value
Hz
0
8-23
6
3rd speed
LL to UL setting value
Hz
0
8-23
6th speed
LL to UL setting value
Hz
0
8-23
7th speed
LL to UL setting value
Hz
0
8-23
5th speed
LL to UL setting value
Hz
0
8-23
4th speed
LL to UL setting value
Hz
0
8-23
5 - 7
2ND
Pattern drive time
0 to 8000
sec
0
8-28
8
#1 to 7
to
min
Pattern drive characteristics
0: Forward run, #1 ACC/DEC
#1 to 7
to
1: Forward run, #2 ACC/DEC
0
8-28
F/R, ACC/DEC
2: Reverse run, #1 ACC/DEC
3: Reverse run, #2 ACC/DEC
Preset Functions Required To Perform the Pattern Run
Reverse run
Forward run
0
Output frequency
Summary of Contents for TOSVERT-130G2+
Page 112: ...TOSHIBA 10 6 Schematics 10 17 ...