TOSHIBA
8.4.3
Jog (Cont'd)
Terminal Connections
Action
ST
F
R
ON
ON
OFF
OFF
Jogging Stop
ON
ON
OFF
ON
Reverse Jogging Run
ON
ON
ON
OFF
Forward Jogging Run
ON
ON
ON
ON
Reverse Jogging Run
JOG
(SS2)
8.4.4
7 Preset Speeds
For remote operation the following preset functions, terminals, and chart must
be used. Follow the same procedure as in section 8.3.4 for setting the preset
speed frequencies.
8 - 15
Terminal inputs and actions
Terminals SS2 and SS3 have dual functions, however only one function can be
used at a time. Enabling the other functions (JOG, AD2) disables functions
SS2 and SS3, thus limiting the number of accessable preset frequencies.
The following chart identifies the functions of the 3 terminals (SS1, SS2, SS3)
and their corresponding accessable preset frequencies.
Setting selection
Terminal Selection 1.tb
Frequency setting
of parameter1.tb AD2/SS3-CC JOG/SS2-CC
SS1-CC
via terminals
OFF
OFF
OFF
Operating frequency set via PP, IV, RR terminals
OFF
OFF
ON
1st operating frequency
0
OFF
ON
OFF
2nd operating frequency
(SS2)
OFF
ON
ON
3rd operating frequency
(SS3)
ON
OFF
OFF
4th operating frequency
ON
OFF
ON
5th operating frequency
ON
ON
OFF
6th operating frequency
ON
ON
ON
7th operating frequency
OFF
OFF
OFF
Operating frequency set via PP, IV, RR terminals
1
OFF
ON
OFF
Jogging
(JOG)
OFF
OFF
ON
1st operating frequency
(SS3)
ON
OFF
OFF
2nd operating frequency
ON
OFF
ON
3rd operating frequency
2
*ON/OFF
OFF
OFF
Operating frequency set via PP, IV, RR terminals
(SS2)
*ON/OFF
OFF
ON
1st operating frequency
(AD2)
*ON/OFF
ON
OFF
2nd operating frequency
*ON/OFF
ON
ON
3rd operating frequency
3
*ON/OFF
OFF
OFF
Operating frequency set via PP, IV, RR terminals
(JOG)
*ON/OFF
ON
OFF
Jogging
(AD2)
*ON/OFF
OFF
ON
1st operating frequency
Terminal Inputs
ST
F
R
CC
SS1
JOG
(SS2)
AD2
(SS3)
F
SS1
SS2
SS3
R
ST
Note:
When "1.tb" (accessible by TB KEY #8) is set to 2 or 3 the AD2 function is activated. This
function enables the user to remotely switch between the ACC/DEC patterns 1 and 2, provided
SEL2=0. If SEL2=1 then the only pattern available is given by ACC2, DEC2, Pt.2. With AD2-CC
terminals shorted (ON) all ACC/DEC patterns are run using the settings of the ACC2, DEC2, Pt.2
parameters.
Terminal Connections Required for
Remote Preset Speeds
Summary of Contents for TOSVERT-130G2+
Page 112: ...TOSHIBA 10 6 Schematics 10 17 ...