Management Software
Using HarnessEye/web
292
❖
Event ID edit box - Specify the event ID. When specifying two or more event IDs,
separate them with a comma. Up to 16 event IDs can be specified. Use a hyphen to
specify a range. If no event ID is specified, all event IDs are applicable.
❖
Description Keyword edit box - Specify the description keyword. The keyword can be
specified with up to 64 characters.
❖
Data Filter Bytes edit box - Specify the data filter bytes in hexadecimal. Up to 64
characters of data can be specified.
❖
Data Filter Offset edit box - When specifying a data filter bytes, specify the data filter
offset position in decimal notation. If no data offset is specified, all offsets are
applicable.
❖
Event Merging Interval edit box- Specify the Event Merging Interval in seconds.
❖
Clear button - Resets the data to their initial state.
❖
Set button - Sets the specified data.
Example 1:
Application log, Error, Example as an event source name, 1234 and 3000 to 3030 as
event IDs, Error as Description Keyword, 1A2B as Data Filter Bytes, second byte as Data
Filter Offset, 60 seconds as Event Merging Interval.
❖
Logfile = Application
❖
Event Type = Error
❖
Event Source = Example
❖
Event ID = 1234, 3000-3030
❖
Description Keyword = Error
❖
Data Filter Bytes = 1A2B
❖
Data Filter Offset = 2
❖
Event Merging Interval = 60
Example 2:
Application log, Error, all as an event source name, all as event IDs, no Description
Keyword, no Data Filter Bytes, no Data Filter Offset, no Event Merging Interval.
❖
Logfile = Application
❖
Event Type = Error
❖
Other Item = Empty