8
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO205L/255/305/355/455
FIRMWARE UPDATING
8 - 33
8.3.4
Finisher firmware (MJ-1025)
Important:
• Be sure to shut down the equipment before installing and removing the download jig.
• Do not shut down the equipment during the update. The data could be damaged and not be
operated properly.
[A] Update Procedure
(1) Install the ROM to the download jig.
Make sure the direction is correct.
(2) Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power
OFF using the main power switch.
(3) Take off the finisher rear cover.
Fig. 8-31
* Connect the finisher interface cable with the equipment after removing the finisher rear cover.
(4) Connect the download jig with the jig connector on the finisher control PC board.
Fig. 8-32
Finisher rear cover
Connector
Summary of Contents for e-studio205L