e-STUDIO205L/255/305/355/455
© 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
6 - 6
EA10
Finisher jam
(Finisher unit)
Paper transport delay jam: The paper which has
passed the bridge unit does not reach the inlet
sensor.
Paper transport delay jam: The paper which has
passed the bridge unit does not reach the inlet
sensor. [MJ-1024/1031/1101]
P. 6-52
EA20
Paper transport stop jam: The paper does not pass
through the inlet sensor. [MJ-1025/MJ-1031]
Paper transport stop jam: The paper has passed
through the inlet sensor but does not reach or pass
the feed path sensor or processing tray sensor.
[MJ-1024]
Paper transport delay jam:
The paper which has passed through the inlet
sensor does not reach the transport sensor. [MJ-
1101]
P. 6-52
EA21
Paper size error jam: Paper does not reach the
sensor because the paper is shorter than spec.
P. 6-53
EA22
Paper transport jam (Finisher paper punching edge
detection sensor):]
P. 6-53
EA23
Paper transport jam (exit sensor)
P. 6-54
EA24
Paper transport jam (between entrance and exit
sensors)
P. 6-54
EA25
Paper transport jam (after paper stack exit)
P. 6-54
EA26
Paper transport jam (stop command request)
P. 6-54
EA27
Paper transport jam (paper not inserted)
P. 6-54
EA28
Paper transport jam (assisting arm operation delay)
P. 6-54
EA29
Paper transport jam (stack transport delay)
P. 6-54
EA30
Power-ON jam: Paper exists at the inlet sensor
when power is turned ON.
P. 6-54
EA31
Transport path paper remaining jam
P. 6-54
EA32
Exit paper remaining jam
P. 6-55
EA40
Door open jam: The Finisher is released from the
equipment or any of the staple door and top cover
is opened during printing. [MJ-1025]
Door open jam: Any of the upper cover and front
cover of the Finisher or any of the upper door and
front door of the Hole Punch Unit is opened during
printing. [MJ-1024]
Joint open jam: The joint is released during printing
or in the standby status. [MJ-1031]
P. 6-55
EA50
Stapling jam: Stapling is not performed properly.
P. 6-56
EA60
Early arrival jam: The inlet sensor detects the paper
earlier than a specified timing.
P. 6-57
EA70
Stack delivery jam: It cannot deliver the stack of
paper on the intermediary process tray to the stack
tray. [MJ-1025]
Stack slider home position error: The stack slider is
not at the home position. [MJ-1031]