5.8.5
Checking and replacing the transfer roller
1. Handling precautions
- Wear gloves to avoid touching the drum surface with your bare hands.
- Do not allow oil or fingerprints to come in contact with the surface.
- Do not hit or scratch the surface.
- Make sure you do not get any bits of thread, etc. on the surface.
- Do not allow solvent, such as thinner, to come in contact with the surface.
- Keep away from a source of heat.
2. Cleaning procedure
If bits of thread or similar adhere to the surface, remove them with gloves or a pair of tweezers. Be
careful that the roller surface is not damaged by the points of the tweezers.