e-STUDIO205L/255/305/355/455
© 2009 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODES
2 - 16
2.4
Test Print Mode (Test Mode 04)
The embedded test pattern can be printed out by keying in the following codes in the test print mode
(04).
Operation procedure
Notes:
1. When an error occurs, it is indicated on the panel, but the recovery operation is not
performed. Turn OFF the power and then back ON to clear the error.
2. During test printing, the [CLEAR] button is disabled when “Wait adding toner” is displayed.
Code
Types of test pattern
Remarks
Procedure
Output from
114
Secondary scanning direction 17
gradation steps
Error diffusion
1
SLG
142
Grid pattern
Pattern width: 2 dots, Pitch:
10 mm
1
LGC
[0][4]
[POWER]
[POWER] OFF/ON
(Exit)
(Code)
[START]
[CLEAR]
Operation
Continuous
Test Printing