3
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO205L/255/305/355/455
ADJUSTMENT
3 - 13
Remark:
When the adjustment (05-421) is performed, the same adjustment for FAX (05-422) is
automatically and consecutively performed.
<Adjustment procedure summarization for A to E>
When the value is 1.
[0] [5] [Power ON] [1] ([3](05-445, 498) for duplexing) [FAX]
A:
05-401 (Lower drawer, A3/LD)
200±0.5 mm (0.125 mm/step)
B:
05-411 (Lower drawer, A3/LD)
52±0.5 mm (0.05 mm/step)
Key in the same value for 05-410.
C:
05-421 (Lower drawer, A3/LD)
200±0.5 mm (0.125 mm/step)
D: 05-440 (Lower drawer, A3/LD), 441 (Lower drawer, A4/LT), 444 (PFP, A4/LT),
443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Duplexing, A3/LD)
52±0.5 mm(0.4 mm/step)
E:
05-498-0 (Lower drawer, A3/LD),
498-1 (Lower drawer, A4/LT))
52±0.5 mm (0.05 mm/step)