8
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO205L/255/305/355/455
FIRMWARE UPDATING
8 - 11
(8)
Press the [ON/OFF] button on the control panel to shut down the equipment, and then r
emove
the USB media.
Note:
When the equipment has been shut down normally, the LCD screen and LEDs (green and red)
go OFF.
When OS data have been updated and the equipment has been shut down immediately after the
update, the LEDs (green and red) may not go OFF even if the LCD screen goes OFF. This
indicates that the equipment is not shut down normally. Press the [ON/OFF] button on the control
panel. 5 seconds or more after the beep, turn the main switch OFF, and then remove the USB
media.
(9) Perform the initialization of the updating data.
• Press the [ON/OFF] button on the control panel while [0] button and [8] button are pressed
simultaneously.
• Key in “947”, and then press the [START] button.
• Press the [INITIALIZE] button.
[B] Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data were overwritten properly.
P.8-50 "8.4 Confirmation of the updated data"
Scanner update Error
Error number
Error message
Error content
S01
Time out
(When the download is requested)
Communication timeout
(When the download is requested)
S02
Time out
(When the download is written)
Communication timeout
(When the download is written)
S03
Time out
(When the download is finished)
Communication timeout
(When the download is finished)
S05
Deletion error
(When the download is written)
Deletion error
(When the download is written)
S06
Writing error
(When the download is written)
Writing error
(When the download is written)
S08
Reception status code abnormality
(When the download is requested)
Reception status code abnormality
(When the download is requested)
S09
Reception status code abnormality
(When the download is written)
Reception status code abnormality
(When the download is written)
S10
Reception status code abnormality
(When the download is finished)
Reception status code abnormality
(When the download is finished)
S00
Other error
Other error