e-STUDIO205L/255/305/355/455
© 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 18
[E] Image position adjustment of the secondary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) Press [FAX] to make a copy at the mode of A3 (LD), 100% and the lower drawer (Refer to *).
(4) Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(5) Check if the distance D is within the range of 10±0.5 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode) (Key in the code [305]) [START]
(Key in a value (acceptable values: 90 to 166))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
(“100% A” is displayed.)
* The larger the adjustment value is, the more the image is shifted to the trailing edge (0.13
mm/step).
Fig. 3-16
10
20
30
40
D
Feeding direction
Copied image of the ruler