e-STUDIO205L/255/305/355/455
© 2009 TOSHIBA TEC CORPORATION All rights reserved
PREVENTIVE MAINTENANCE (PM)
5 - 24
5.7.5
Developer section
Fig. 5-13
* a. Do not use alcohol for cleaning the developer unit.
* b. Developer material
After replacing the developer material, be sure to perform the auto-toner adjustment.
P.3-2 "3.2 Adjustment of Auto-Toner Sensor"
* g. Oil seal
Mixer unit (Shafts of mixers 1, 2 and 3) 6 pcs.
During replacement, coat the oil seal with grease (Alvanian No.2).
Items to check
Cleaning
Lubrication
Replacement
(x 1,000 sheets)
Operation
check
Parts list
<P-I>
a
Whole developer unit
B
b
Developer material
80/100/120/125/
150
c
Front shield
B
R
28-32
d
Guide roller
B
29-17
e
Side shield
B
R
28-30
28-31
f
Developer unit lower stay
B
g
Oil seal (6 pcs.)
AV
480/600/720/750/
900
28-1
29-8
29-12
a
b
f
g
d
e
c