December 2000 © TOSHIBA TEC
2 - 9
DP4500/3500 ADJUSTMENT
(e) Image position adjustment of the primary scanning direction during duplex printing (the adjustment of
the laser writing start position)
(e-1) Adjustment for long-sized paper
1. Turn ON the power while the digital keys [0] and [5] are pressed simultaneously.
n
(Adjustment mode)
2. Press [3]
n
[FAX] (A grid pattern is printed out on both sides of the paper: Use A3 (LD) in the lower
cassette.)
3. Check the grid pattern on the back side of the paper. Measure the distance E from the leading edge of
the paper to the 6th line of the grid pattern.
4. Check if the distance E is in the range of 52 ± 0.5 mm.
5. If not, change the value taking the following procedure and measure the distance E again.
<Procedure>
(Adjustment mode)
n
(Enter the code [498] with the digital keys)
n
Press [0]
n
[START]
n
(Enter a value (acceptable values: 0 to 255) with the digital keys)
n
Press the [SET] icon or the [INTERRUPT] key to store the value in the RAM.
n
“100% A” is displayed.
n
Press [3]
n
[FAX]
n
(Grid patterns are printed out on both sides of the paper)
*The larger the adjustment value, the longer the distance E becomes
(approx. 0.5 mm/10 steps).
(e-2) Adjustment for short-sized paper
After the adjustment for long-sized paper is completed, apply the same adjustment value for short-sized
paper.
<Procedure>
(Adjustment mode)
n
(Enter the code [498] with the digital keys)
n
Press [1]
n
[START]
n
(Enter the same value entered for long-sized paper with the digital keys)
n
Press the [SET] icon or the [INTERRUPT] key to store the value in the RAM.
Note: The first line of the grid pattern is occasionally not printed out.
Summary of Contents for DP3500
Page 91: ...DP4500 3500 PREVENTIVE MAINTENANCE 3 12 December 2000 TOSHIBA TEC ...
Page 95: ...DP4500 3500 SUPPLIES 4 4 December 2000 TOSHIBA TEC ...
Page 213: ...DP4500 3500 TROUBLESHOOTING 5 118 December 2000 TOSHIBA TEC ...
Page 253: ...DP4500 3500 UPDATING THE FIRMWARE 6 40 December 2000 TOSHIBA TEC ...
Page 256: ...DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 4 December 2000 TOSHIBA TEC ...