December 2000 © TOSHIBA TEC
5 - 31
DP4500/3500 TROUBLESHOOTING
[EA2] Finisher paper transport stop jam
MJ-1011
Is there any paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the connector J10 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and inlet sensor (S2D) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the inlet sensor working properly? (Check the movement of the actuator.)
NO
1. Connect the connector of the inlet sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet sensor.
YES
Replace the finisher controller PC board.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
Summary of Contents for DP3500
Page 91: ...DP4500 3500 PREVENTIVE MAINTENANCE 3 12 December 2000 TOSHIBA TEC ...
Page 95: ...DP4500 3500 SUPPLIES 4 4 December 2000 TOSHIBA TEC ...
Page 213: ...DP4500 3500 TROUBLESHOOTING 5 118 December 2000 TOSHIBA TEC ...
Page 253: ...DP4500 3500 UPDATING THE FIRMWARE 6 40 December 2000 TOSHIBA TEC ...
Page 256: ...DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 4 December 2000 TOSHIBA TEC ...