![Toshiba DP3500 Service Handbook Download Page 131](http://html.mh-extra.com/html/toshiba/dp3500/dp3500_service-handbook_425114131.webp)
DP4500/3500 TROUBLESHOOTING
5 - 36
December 2000 © TOSHIBA TEC
Is the joint sensor working properly?
NO
1. Connect the connector of the joint sensor securely.
2. Replace the joint sensor.
YES
Is the door of the finisher closed?
NO
Close the door.
YES
Is the connector J12 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and door opening sensor (PI16) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the door opening sensor working properly?
NO
1. Connect the connector of the door opening sensor securely.
2. Replace the door opening sensor.
YES
Is the connector J5 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and door switch (MS1) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the door switch working properly?
NO
1. Connect the connector of the door switch securely.
2. Replace the door switch.
YES
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼