December 2000 © TOSHIBA TEC
5 - 45
DP4500/3500 TROUBLESHOOTING
[EAB] Saddle stitcher transport stop jam
MJ-1013 (Saddle stitcher section)
Is there any paper remaining on the transport path in the finisher, saddle stitcher section or main unit?
YES
Remove the paper.
NO
Is the conncetor J17 on finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and inlet sensor (PI1) open-circuited?
Is either of the connectors J10 or J9 on the saddle stitcher controller PC board disconnected?
Is the harness connecting the saddle stitcher controller PC board and No.1 paper sensor
(PI18S) open-circuited?
Is the harness connecting the saddle stitcher controller PC board and No.2 paper sensor
(PI19S) open-circuited?
Is the harness connecting the saddle stitcher controller PC board and No.3 paper sensor
(PI20S) open-circuited?
Is the harness connecting the saddle stitcher controller PC board and delivery sensor
(PI11S) open-circuited?
YES
Connect the connectors securely. Replace the harnesses.
NO
Is the inlet sensor working properly? (Check the movement of the actuator.)
Is the No.1 paper sensor working properly? (Check the movement of the actuator.)
Is the No.2 paper sensor working properly? (Check the movement of the actuator.)
Is the No.3 paper sensor working properly? (Check the movement of the actuator.)
Is the delivery sensor working properly? (Check the movement of the actuator.)
NO
1. Connect the connectors of the sensors securely.
2. Attach the actuators securely if their shafts are out of place.
3. Replace the sensors.
YES
Replace the saddle stitcher controller PC board.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
Summary of Contents for DP3500
Page 91: ...DP4500 3500 PREVENTIVE MAINTENANCE 3 12 December 2000 TOSHIBA TEC ...
Page 95: ...DP4500 3500 SUPPLIES 4 4 December 2000 TOSHIBA TEC ...
Page 213: ...DP4500 3500 TROUBLESHOOTING 5 118 December 2000 TOSHIBA TEC ...
Page 253: ...DP4500 3500 UPDATING THE FIRMWARE 6 40 December 2000 TOSHIBA TEC ...
Page 256: ...DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 4 December 2000 TOSHIBA TEC ...