DP4500/3500 TROUBLESHOOTING
5 - 12
December 2000 © TOSHIBA TEC
[E13] Upper cassette misfeeding (paper not reaching the upper feed sensor)
Open the jam access cover. Is there any paper in front of the upper feed sensor?
YES
Remove the paper.
NO
Is the upper feed sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[6]/[E])
NO
1. Check if the connector of the upper feed sensor is disconnected.
2. Check if the connector J313 on the LGC board is disconencted.
3. Check if the connector pins are disconnected and the harnesses are open-circuited.
4. Check if the conductor pattern on the LGC board is short- or open-circuited.
5. Replace the upper feed sensor.
6. Replace the LGC board.
YES
Is the upper cassette feed clutch working?
(Perform the output check in the test mode: 03-201)
NO
1. Check if the connector of the upper cassette feed clutch is disconnected.
2. Check if the connector J310 on the LGC board is disconnected.
3. Check if the connector pins are disconnected and the harnesses are open-
circuited.
4. Check if the conductor pattern on the LGC board is short- or open-circuited.
5. Replace the upper cassette feed clutch.
6. Replace the LGC board.
YES
Check the upper cassette feed roller and separation roller. Replace them if they are worn out.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
Summary of Contents for DP3500
Page 91: ...DP4500 3500 PREVENTIVE MAINTENANCE 3 12 December 2000 TOSHIBA TEC ...
Page 95: ...DP4500 3500 SUPPLIES 4 4 December 2000 TOSHIBA TEC ...
Page 213: ...DP4500 3500 TROUBLESHOOTING 5 118 December 2000 TOSHIBA TEC ...
Page 253: ...DP4500 3500 UPDATING THE FIRMWARE 6 40 December 2000 TOSHIBA TEC ...
Page 256: ...DP4500 3500 WIRE HARNESS CONNECTION DIAGRAMS 7 4 December 2000 TOSHIBA TEC ...