December 2000 © TOSHIBA TEC
5 - 35
DP4500/3500 TROUBLESHOOTING
[EA4] Finisher front door opened during printing
MJ-1011
Is there any paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the finisher connected with the main unit?
NO
Connect the finisher with the main unit.
YES
Is the connector J11 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and joint sensor (S4D) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the joint sensor working properly?
NO
1. Connect the connector of the joint sensor securely.
2. Replace the joint sensor.
YES
Replace the finisher controller PC board.
MJ-1012/1013 (Finisher section)
Is there any paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the finisher connected with the main unit?
NO
Connect the finisher with the main unit.
YES
Is the connector J12 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and joint sensor (PI15) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼