![Toshiba DP3500 Service Handbook Download Page 128](http://html.mh-extra.com/html/toshiba/dp3500/dp3500_service-handbook_425114128.webp)
December 2000 © TOSHIBA TEC
5 - 33
DP4500/3500 TROUBLESHOOTING
[EA3] Paper remaining inside the finisher at power ON
MJ-1011
Is there any paper remaining on the transport path in the finisher?
YES
Remove the paper.
NO
Is the connector J10 on the finisher controller PC board disconnected?
Is the harness connecting the finisher controller PC board and inlet sensor (S2D) open-circuited?
YES
Connect the connector securely. Replace the harness.
NO
Is the inlet sensor working properly? (Check the movement of the actuator.)
NO
1. Connect the connector of the inlet sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet sensor.
YES
Replace the finisher controller PC board.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼