- 19 -
4.6 Set clock (calendar year, month, date and time) of the display before use.
NOTE When tightening torque is measured without microSD memory card, the clock
is used only for purpose of “5-6 Display setting state and battery power
level” (See Page 19.) In this case, setting the clock is not necessary.
4.7 Activate or deactivate an
“
Auto Start Mode
”
before use.
Zero adjustment is automatically made right before each torque measurement
when auto start is ON.
Manual zero adjustment is necessary each time before torque measurement
when auto start is OFF. Battery last longer when auto start is OFF.
Refer
“
Using Display
”
on page 25.
4.8 About 5 minutes of warm up exercise at no-load is necessary for precise torque
measurement.
CAUTION
●
The torque control wrench tend to stop right after the wrench is
activated when it is set for minimum torque value and is use in
temperature below 10 degrees centigrade. In such case set
torque setting dial at maximum and exercise the wrench for about 5
minutes then reset the torque to target torque.